Set Pulses

This is a purpose Set pulse output value by method specified in C2 and S for the specified port C1. PULS(886) is used to set parameters for pulse outputs that are started later in the program using SPED(885) or ACC(888).

                                 
  C1: Port Specifier

Value (HEX) mearing
0000 Puls Output 0
0001 Puls Output 1

  C2: Pulse Type

Value (HEX) mearing
0000 Relative
0001 Absolute

  S:Number of Pulse
    
N Lower word with number of pulses
N+1 Upper word with number of pulses
         





Google Search

Main manu
Home
Download  
About Us
Learn PLC
Book
Product
PLC Secondhand
Contact Us
 



 Home  |  Download  | About us  |  Link to Us  |  Learn plc  |  Book  Product | PLC Secondhand | Contact us
                                                            Copyright@2006 by http://www.try-plc.com
                                          All rights reserved. Any comment please contact try-plc@try-plc.com